GAMMA SERIES
Aqualine reverse Osmosis Systems successfully ensures that pure water is obtained as a result of this process. In addition, Aqualine Reverse Osmosis Systems can be produced in different design styles according to customer requests.
150 m3 / day to 1650 m3 / d
more information
150 m3 / day to 1650 m3 / d
more information
Price on request
STANDARD FEATURES
- Membrane Vessels FRP
- TFC Spiral wound membranes 8 "diameter
- AISI304 or AISI316 stainless steel vertical centrifugal high pressure pump
- ST-37 Epoxy painted carbon steel or AISI304 Stainless Steel Skid
- 5 Micron precision cartridge filter
- Low pressure line U-PVC PN16
- High pressure line AISI304 Stainless steel
- Inlet electric actuated butterfly valve
- Pressure regulating globe valves at pump outlet and wastewater line
- Low and high pressure switch
- Product water and waste water flow meters
- Glycerine manometers
- Product water conductivity indicator (0-2000µS / cm)
- Product water pH meter (optional)
- Autoflush, automatic rinsing and chemical washing system
- On-Off switch
- PLC and operator panel
- 380 V / 50Hz / 3ph
- IP56 control panel
Recommended Inflow Water Limits
- Inlet water TDS: 0 - 2,000 ppm
- Working pressure: between 10 and 15 bar
- Inlet water pressure: 2 to 5 bar
- If hardness is more than 3 French ASC dosage required.
- pH range: 6 - 8
- Silica (SiO2) Tolerance: 25 ppm max. @ 60% efficiency
- Max. Inlet water temperature = 30º C Max.
- Max Iron (Fe) tolerance: 0.05 ppm, if ASC is dosed 0.2 ppm
- Hydrogen Sulfide should not be.
- There should be no turbidity (NTU<1)
- SDI < 5
- Microbiological contamination should be removed